Skip to content

G.S LOUISE MICHEL - AQUATAIR

2 minute read
|
June 5, 2024

Share this post:

Trimble Construction Awards 2024, G.S LOUISE MICHEL, AQUATAIR

About the project

Category: Tertiary HVAC-Elec. project Project name: G.S LOUISE MICHEL Company: AQUATAIR Project location: ANEMASSE (74), France Client: Ville d'Annemasse Architect: NUNC Architectes B.E Fluides: EPCO Energies

The project in pictures

Trimble Construction Awards 2024, G.S LOUISE MICHEL, AQUATAIR
Trimble Construction Awards 2024, G.S LOUISE MICHEL, AQUATAIR
Trimble Construction Awards 2024, G.S LOUISE MICHEL, AQUATAIR
Trimble Construction Awards 2024, G.S LOUISE MICHEL, AQUATAIR
Trimble Construction Awards 2024, G.S LOUISE MICHEL, AQUATAIR
Trimble Construction Awards 2024, G.S LOUISE MICHEL, AQUATAIR
Trimble Construction Awards 2024, G.S LOUISE MICHEL, AQUATAIR
Trimble Construction Awards 2024, G.S LOUISE MICHEL, AQUATAIR
Trimble Construction Awards 2024, G.S LOUISE MICHEL, AQUATAIR

The project in figures

Surface area: 5,968.23 m² Cost of HVAC work: 1,679,615.09 Euros incl. VAT for the HVAC package

Trimble products used

Trimble Nova Trimble Connect

Project description

This project involves the construction of a new school complex to accommodate children from kindergarten to primary school. It also includes a crèche and a gymnasium. It is being built within the framework of the city of Annemasse to meet the growing needs of our department.

The school complex was designed to be a PASSIVE building. From its composition to its structure (specific concrete to respect passivity), internal partitions made of terracotta, also a wooden architecture for the floors as well as the floors between levels.

Our ventilation and heating package has been designed to meet the standards of a passive building. For heating, we use a heat pump coupled with geothermal energy. Our heating networks are low-temperature, and we supply low-temperature community radiators, radiant panels and hydraulic coils for the air handling units. This heating network is reversible, which means we have to comply with the appropriate insulation class.

Our company has been selected to supply the HVAC package.

We are in charge of sizing, layout and positioning all HVAC equipment, as well as finding the best technical solution.

Produce working drawings and schematics

Challenges to meet

  • Compliance with Passivhauss certification

  • E4 C2 carbon footprint < 750 kgCO2/m2SP.an

  • Geothermal energy

  • Environmentally-friendly worksite with reduced traffic and paper documents

  • 3rd category ERP building with type R, N and X activities as defined by fire regulations

AQUATAIR's main role

Execution/Installation

Related articles

Article

Randselva bridge: closing the gap on drawing‑free design

Randselva Bridge in Norway is the world’s longest bridge to be designed and constructed using only B...
Read full article
Article

Visualize and build automated warehouse systems with SketchUp

Senior Applications Engineer at TGW, an international provider of warehouse automation solutions, sh...
Read full article
Article

What are Digital Twins?

A digital twin in construction is a dynamic, living digital replica of a physical asset—such as a bu...
Read full article